Advanced suction caisson capacity analysis software for combined vertical, horizontal and moment (VHM) loading. Designed for offshore wind, oil & gas foundation design.
TRUSTED BY LEADING COMPANIES WORLDWIDE
Full 3D interaction surface generation for combined loading assessment
Faster than manual calculations
Foundation Capacity Analysis Software
OVERVIEW
Caisson VHM is a specialist tool for analysing the capacity of suction caisson foundations under combined vertical, horizontal and moment loading conditions.
OVERVIEW
Caisson VHM performs capacity calculations for suction caisson foundations subjected to combined loading. The software models the interaction between vertical, horizontal and moment loads using advanced failure envelope methods. It supports both undrained and drained soil conditions and accounts for caisson geometry, embedment depth, and soil strength profiles
PURPOSE
Caisson VHM is a design tool used in the offshore industry to evaluate suction caisson foundation capacity. It generates VHM failure envelopes that define the allowable load combinations for a given caisson geometry and soil profile. Engineers use it to verify foundation adequacy under environmental and operational loading conditions
CAPABILITIES
Automatically generate 3D failure envelopes showing interaction between vertical, horizontal and moment capacities.
Support for linearly increasing undrained shear strength, drained soil parameters, and custom soil profiles.
Automated parametric studies and batch processing for efficient sensitivity analyses across multiple load cases.
Model complex caisson geometries including stiffened skirts, internal compartments, and variable wall thickness.
Evaluate flap mechanism contributions to lateral and moment capacity for detailed foundation assessment.
Built-in sensitivity analysis tools to evaluate the impact of key parameters on foundation capacity.
Visualise complete VHM interaction diagrams with cross-sections at specified load levels.
Store and manage soil data, caisson geometries, and analysis configurations in organised databases.
Cloud-based platform accessible from any modern browser on Windows, Mac, or Linux.
TECHNICAL DETAILS
Determine the ultimate capacity of suction caisson foundations under combined VHM loading. Calculate failure envelopes for design verification and optimise caisson dimensions.
Run advanced capacity calculations using multiple soil models. The analysis engine handles undrained and drained conditions with depth-dependent strength profiles.
Generate comprehensive results including VHM interaction diagrams, load-displacement curves, and detailed PDF reports ready for client submission.
Software as a Service
XXX
Modular analysis framework with configurable calculation methods and soil models.
Structured data input with comprehensive results and PDF reports.
Single analysis, parametric study and batch processing modes.
x
x
x
x
x
x
x
x
Single analysis, parametric study, and batch processing modes.
Browser-based interface accessible from any modern device.
PRODUCT PREVIEW
XXX
X
X
X
X
PRODUCT PREVIEW
Use our bespoke templates, Excel files and over 800+ documentation and best practices. And as always, here to help and assist to get you started with Caisson VHM.
Best practices, technical guides, and reference manuals curated by industry experts
Ready-to-use project templates to standardise your workflow and save setup time.
Pre-built Excel files for data preparation, parameter studies, and result post-processing.
We’re always here to help and assist you getting started with Caisson VHM.
TRUSTED BY ENGINEERS
Use our bespoke templates, Excel files and over 800+ documentation and best practices. And as always, here to help and assist to get you started with Caisson VHM.
Oene-Jeljer Dijkstra
Geotechnical Engineer Manager
DEME / SPT Offshore
Hank
Senior Geotechnical Manager
MatDan
Oene-Jeljer Dijkstra
Geotechnical Engineer Manager
DEME / SPT Offshore
FAQ
If you have more questions please give us a buzz.
VHM analysis evaluates the combined capacity of suction caisson foundations under Vertical (V), Horizontal (H), and Moment (M) loading. It defines the failure envelope — the boundary of safe load combinations — essential for offshore foundation design.
Caisson VHM supports linearly increasing Su, constant undrained shear strength, drained soil parameters (φ, c'), multi-layer profiles, custom Su/s'v ratios, and remoulded strength profiles for installation analysis.
The software uses upper bound plasticity methods and failure envelope interpolation techniques, fully aligned with ISO 19901-4, API RP 2GEO, and DNV-RP-C212 standards to generate accurate 3D interaction surfaces.
Yes. Caisson VHM is designed to comply with ISO 19901-4, API RP 2GEO, and DNV-RP-C212 standards, making it suitable for formal foundation design verification and client submissions.
Yes. Caisson VHM is designed to comply with ISO 19901-4, API RP 2GEO, and DNV-RP-C212 standards, making it suitable for formal foundation design verification and client submissions.
Outputs include 3D VHM interaction surfaces, 2D cross-section plots, load-displacement curves, tabulated capacity data, professional PDF reports, and CSV/Excel exports.
No installation required. Caisson VHM is fully cloud-based and accessible from any modern browser on Windows, Mac, or Linux.
FLEXIBLE PLANS
For Individual Engineers
per year, per user
For Your Team
for your team
For Individual Engineers
tailored pricing
Get in touch for a personalised demo or quote.
Professional geotechnical engineering software built for the offshore industry.
Contact